Search results for "high attenuation"

showing 2 items of 2 documents

Using coded excitation to maintain signal to noise for FMC+TFM on attenuating materials

2019

Ultrasonic Non-Destructive Evaluation using Full Matrix Capture (FMC) and Total Focusing Method (TFM) is used for high resolution imaging as every pixel is in optimal focus. FMC excites one element in turn, so operates with lower transmitted energy compared to phased array beamforming. The energy at a reflector is further reduced by the broad directivity pattern of the single element. The large number of Tx/Rx A-scans that contribute to each pixel recover the Signal-to-Noise Ratio (SNR) in the final TFM image. Maintaining this in the presence of attenuating materials is a challenge because relevant information in each A-scan signal is buried in the thermal noise, and the TFM process assumes…

BeamformingComputer sciencePhased arrayAcousticsTK02 engineering and technology01 natural sciencesSignalNoise (electronics)Signal-to-noise ratio0103 physical sciencesTFMUltrasound0202 electrical engineering electronic engineering information engineeringFMChigh attenuation010301 acousticsPixelbusiness.industryQuantization (signal processing)AttenuationUltrasoundorthogonal Golay code020206 networking & telecommunicationsCoded excitationRough surfaceUltrasonic sensorbusinessadditive manufacturingEnergy (signal processing)
researchProduct

Comparison of Iodine Quantification and Conventional Attenuation Measurements for Differentiating Small, Truly Enhancing Renal Masses From High-Atten…

2019

OBJECTIVE. The purpose of this study is to determine whether iodine quantification techniques from contrast-enhanced dual-energy CT (DECT) data allow equal differentiation of small enhancing renal masses from high-attenuation (> 20 HU of unenhanced attenuation) nonenhancing lesions, compared with conventional attenuation measurements. MATERIALS AND METHODS. A total of 220 nonconsecutive patients (mean [± SD] age, 66 ± 13 years; 130 men and 90 women) with 265 high-attenuation renal lesions (mean attenuation, 54 ± 33 HU; 91 enhancing lesions) were included. Each patient underwent single-energy unenhanced CT followed by DECT during the nephrographic phase using one of four different high-en…

Renal lesionDual energyEnhancementbusiness.industryAttenuationchemistry.chemical_elementGeneral MedicineIodine030218 nuclear medicine & medical imagingDual energy03 medical and health sciences0302 clinical medicineIodine quantificationchemistry030220 oncology & carcinogenesisRenal lesionMedicineRadiology Nuclear Medicine and imagingDual energy ctNuclear medicinebusinessHigh attenuationAJR. American journal of roentgenology
researchProduct